CFD analysis of Thermal Comfort & Contaminant removal from a typical Hospital Operation Theater

Show simple item record

dc.contributor.author Alam, Tousif Bin
dc.date.accessioned 2021-10-12T09:44:35Z
dc.date.available 2021-10-12T09:44:35Z
dc.date.issued 2012-11-15
dc.identifier.citation [1] AIA, AIA Guidelines for Design and Construction of Hospitals and Health Care Facilities, The American Institute of Architects, Washington, DC, 2001. [2] ASHRAE, ASHRAE Handbook: Applications, American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., Atlanta, GA, 2003. [3] J.E. Woods, D.T. Brayman, R.W. Rasmussen, P.E. Reynolds, G.M. Montag, Ventilation requirements in hospital operating rooms. Part I: Control of airborne particles, ASHRAE Transactions 92 (2) (1986) 396–426. [4] J.R. Lewis, Operating room air distribution effectiveness, ASHRAE Transactions 99 (2) (1993) 1191–1199. [5] F. Memarzadeh, Methodology for minimizing risk from airborne organisms in hospital isolation rooms, ASHRAE Transactions 106 (2) (2000) 731–742. [6] F. Memarzadeh, A. Manning, Reducing risks of surgery, ASHRAE Journal 45 (2) (2003) 28–33. [7] R. Mora, M. English, A. Athienitis, Assessment of thermal comfort during surgical operations, ASHRAE Transactions 107 (1) (2001) 52–62. [8] P.O. Fanger, Thermal Comfort: Analysis and Applications in Environmental Engineering, McGraw-Hill, New York, 1970. [9] C.A. Balaras, E. Dascalaki, A.A. Argiriou, A. Gaglia, HVAC systems and indoor conditions in Hellenic hospital operating rooms, ASHRAE Transactions 108 (2) (2002) 23–38. [10] R. ameel, E.E. halil, Energy efficient and hygienic operating theatres’ HVAC airside design architectural and engineering consideration, in: Proceedings of First International Energy Conversion Engineering Conference, Portsmouth, VA, 2003, AIAA 2003-5997. 64 | P a g e [11] E.E. Khalil, R. Kameel, Requirements of air-conditioning systems’ developments in hospitals and critical healthcare facilities, in: Proceedings of the Seventh Biennial Conference on Engineering Systems Design and Analysis, vol. 3, 2004, pp. 375–381. [12] F. Memarzadeh, A. Manning, Thermal comfort, uniformity, and ventilation effectiveness in patient rooms: performance assessment using ventilation indices, ASHRAE Transactions 106 (2) (2000) 748–761. [13] D.J. Hirnikel, P.J. Lipowicz, R.W. Lau, Predicting contaminant removal effectiveness of three air distribution systems by CFD modeling, ASHRAE Transactions 108 (1) (2002) 350-359. [14] F. Memarzadeh, A. Manning, Comparison of operating room ventilation systems in protection of the surgical site, ASHRAE Transactions 108 (2) (2002) 3–15. [15] R. Kameel, Assessment of airflow characteristics in air-conditioned spaces using 3D time-dependent CFD model, in: Proceedings of First International Energy Conversion Engineering Conference, Portsmouth, VA, 2003, AIAA 2003- 5960. [16] T.T. Chow, X.Y. Yang, Performance of ventilation system in a nonstandard operating room, Building and Environment 38 (12) (2003) 1401–1411. [17] B. Jayaraman, A.H. Kristoffersen, E.U. Finlayson, A.J. Gadgil, CFD investigation of room ventilation for improved operation of a downdraft table – novel concepts, Journal of Occupational and Environmental Hygiene 3 (11) (2006) 583–591. [18] C.G. Helmis, J. Tzoutzas, H.A. Flocas, C.H. Halios, O.I. Stathopoulou, V.D. Assimakopoulos, V. Panis, M. Apostolatou, G. Sgouros, E. Adam, Indoor air quality in a dentistry clinic, Science of the Total Environment 377 (2–3) (2007) 349–365. [19] Z. Rui, T. Guangbei, L. Jihong, Study on biological contaminant control strategies under different ventilation models in hospital operating room, Building and Environment 43 (5) (2008) 793–803. [20] W.M. Kays, M.E. Crawford, B. Weigand, Convective Heat and Mass Transfer, fourth ed., McGraw-Hill, New York, 2005. 65 | P a g e [21] ASHRAE, ASHRAE Handbook: Fundamentals, American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., Atlanta, GA, 2005. [22] ANSI/ASHRAE Standard 55-2004: Thermal Environmental Conditions for Human Occupancy, American Society of Heating, Refrigerating and Air- Conditioning Engineers, Inc., Atlanta, GA, 2004. [23] ANSI/ASHRAE Standard 62.1-2004: Ventilation for Acceptable Indoor Air Quality, American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., Atlanta, GA, 2004. [24] StatSoft, Electronic Statistics Textbook, StatSoft, Inc., Tulsa, OK, 2006. Available from: <http://www.statsoft.com/textbook/stathome.html>. [25] G.E.P. Box, J.S. Hunter, W.J. Hunter, Statistics for Experimenters: Design, Innovation, and Discovery, second ed., John Wiley & Sons, Inc., Hoboken, NJ, 2005. [26] Fluent, Inc., FIDAP, CFD Analysis Software, 2005. Available from: <http:// www.fluent.com/>. [27] Fluent, Inc., GAMBIT, Mesh Generation Software, 2006. Available from: <http:// www.fluent.com/>. [28] C.A.J. Fletcher, Computational Galerkin Methods, Springer-Verlag, New York, 1984. [29] S.R. Searle, Linear Models, John Wiley & Sons, Inc., Hoboken, NJ, 1971. en_US
dc.identifier.uri http://hdl.handle.net/123456789/1191
dc.description Supervised by DR. A. K. M. Sadrul Islam Professor Department of Mechanical and Chemical Engineering (MCE), Islamic University of Technology (IUT) Board Bazar, Gazipur, Dhaka, Bangladesh. en_US
dc.description.abstract This Thesis paper presents CFD analysis of Thermal Comfort & Contaminant removal from a typical Hospital Operation Theater. This is a three dimensional analysis. The operation theater model includes a patient lying on an operating table, four surgical staff members standing around, and surgical lights above the patient. Cold clean air is supplied to the room through high sidewall grilles and exhausted through low sidewall grilles on the opposite wall. Steady state heat and mass transfer in the room are simulated by employing computational fluid dynamics modeling approach. Solutions of the distribution of airflow velocity, temperature, pressure, relative humidity, and contaminant concentration are presented and discussed. The predicted mean vote (PMV) is calculated for assessing thermal comfort of the occupants. The contaminant removal effectiveness (CRE) and the mean contaminant concentration in the breathing zone are used to assess the ventilation performance of the room. Effects of horizontal locations of supply and exhaust grilles on thermal comfort and contaminant removal are explored. Regression models for thermal comfort and contaminant removal as functions of these locations are built for design optimization. It is found that an overall better performance can be achieved by placing the supply grilles closer to the vertical centerline of the wall while the location of the exhaust grilles is somewhat insignificant. en_US
dc.language.iso en en_US
dc.publisher Department of Mechanical and Production Engineering (MPE),Islamic University of Technology(IUT), Board Bazar, Gazipur, Bangladesh en_US
dc.title CFD analysis of Thermal Comfort & Contaminant removal from a typical Hospital Operation Theater en_US
dc.type Thesis en_US