Abstract:
In recent times fire incidents are one of the major hazards in our country which was happening
because of some lacking of awareness on fire safety management, reluctant behavior in building
safety codes or guidelines, and inadequate fire extinguishers. Recently back-to-back fire-related
accidents also give us a wave of awareness for the safety of our future generations, respective
teachers, and staffs who may spend their half of time in educational institutions. So, the safety of
educational institutions is essential to each and every one for awarding them and able to make
suitable decisions in case of emergencies. The overall purpose of our study was to assess the fire
safety of the academic buildings, namely the First Academic Building and the Second Academic
Building of IUT. We took our campus as a test subject. The data collection was minimal but
sufficient to run the program and get the desired outcome from it. For this we have done firstly,
to operate a fire propagation program which will help the research to predict the occupant
behavior during a fire. And secondly, to propose a new fire evacuation plan with an improved,
efficient, and technologically much more advanced system according to guidelines. For this
purpose, simulations using PyroSIM and Pathfinder software. With PyroSIM the conditions of
heat and smoke caused by a hypothetical fire source were simulated. With Pathfinder the
evacuation scenarios were simulated. The buildings were compared with local guidelines. Some
key findings were derived from these endeavors. For the room where the fire source was located,
the heat and smoke are less when the windows are open and the room is bigger. With regards to
local guidelines, the times of evacuation are acceptable, however, there are significant
shortcomings such as lack of markings for emergency pathways, lack of fire alarms, fire exits,
etc. For each simulation in Pathfinder, we have got the results for both male and female
occupants with their evacuation time and traveled distance to reach the one exit and in the same
time simulating PyroSIM it will show the exact time it will take to spread the fire and smoke all
over the room and that can give an approximate time to design an efficient fire escape route.
Besides this, there is an improved and efficient fire evacuation proposal, and the findings of
major deficiencies for fire safety of our study area are also mentioned. This project there
conducted a comparison study between the proposed civil structure dimensions with the already
available local guidelines and a management plan for the future also
Description:
Supervised by
Mr. Ijaj Mahmud Chowdhury,
Assistant Professor,
Department of Civil & Environmental Engineering,
Islamic University of Technology (IUT),
Board Bazar, Gazipur-1704, Bangladesh.