dc.identifier.citation [1] Posner, J.D., Buchanan, C.R. and Dunn-Ranking, D., 2003, “Measurement and Prediction of Indoor Air Flow in a Model Room”, Journal of Energy and Building, Issue no. 35, pp. 515-526. [2] Wisconsin Department of Health Services, USA, 2012. http://www.dhs.wisconsin.gov/eh/chemfs/fs/carbondioxide.htm [3] ANSYS CFX-12.1 Documentation Release 12.1, 2009 by ANSYS, Inc., USA. [4] Kirkwood, B., Gove, S., Rogers, S., LobLevyt, J., Arthur, P. and Campbell, H., 1995, “Potential interventions for the prevention of childhood pneumonia in developing countries: a systematic review”, Bull. World Health Organ. , 73, 793–798. [5] Bruce, N., 1999, “Lowering Exposure of Children to Indoor Air Pollution to Prevent ARI: the Need for Information and Action”, Capsule Report (3), Arlington, VA, Environmental Health Project. [6] WHO, 2001, “Informal Consultation on Epidemiologic Estimates for Child Health”, Geneva, Department of Child and Adolescent Health Development, WHO. Available at: http:// www.who.int/child-adolescen t-health/ New Publications/CHILD_HEALTH/ Report-of-CHERG-meeting.html. [7] Murray, C. and Lopez, A., 1996, “The Global Burden of Disease”, Cambridge, MA, Harvard School of Public Health, WHO, World Bank. [8] Smith, K., 1993, “Fuel combustion, air pollution exposure, and health: the situation in developing countries”, Annual. Rev. Environ. Energy, 18 , 526– 566. [9] Smith, K. and Metha, S., 2000, “The Global Burden of Disease from Indoor Air Pollution in Developing Countries: Comparison of Estimates”, Prepared for the WHO/ USAID Global Technical Consultation on Health Impacts of Indoor Air Pollution in Developing Countries. [10] Awbi, H. B., and Allwinkle, S. J., 1986, “Domestic Ventilation with Heat Recovery to Improve Indoor Air Quality”, Energy and Buildings, 9, 305– 312. 132 [11] Kondo, Y., Akabayashi, S., Nagase, O. and Matsuda, A., 1998, “Numerical Simulation of Ventilation Efficiency in Commercial Kitchen”, proceedings of Roomvent 98: 6th International Conference on Air Distribution in Rooms, Stockholm, Sweden, [12] Park M., Lee D., Kim K., and Lee J., 2000, “Prediction of the Ventilation Performance in a Kitchen with Various Locations of Gas Range and Window”, PHOENICS User Conference Proceedings. [13] Chi-ming Lai, 2005, “Assessment of Side Exhaust Systems for Residential Kitchens in Taiwan”, Building Services Engineering Research and Technology, Vol. 26, No. 2, 157-166. [14] Nantka M., B., 2006, “Indoor Conditions in Silesian Buildings with Natural Ventilation”, Indoor Built Environ;15;6:571–582. [15] Kajtar, L., and Leitner, A., 2007, “CFD Modeling of Indoor Air Quality and Thermal Comfort”, Proceedings of the 2nd IASME / WSEAS International Conference on Continuum Mechanics, Portoroz, Slovenia. [16] [16] Odunze N., Mishra R., and Reed J., 2007, “The CFD analysis of the effects of the size and location of an Air-Inlet in domestic kitchen extraction”, School of Computing and Engineering Researchers Conference, University of Huddersfield. [17] Panagopoulos, I., Karayannis, A., Kassomenos, P., and Aravossis, K., 2009, “A CFD Simulation Study of VOC and Formaldehyde Indoor Air Pollution Dispersion in an Apartment as Part of an Indoor Pollution Management Plan”, Proceedings of the 2nd International CEMEPE, SECOTOX Conference, Mykonos, ISBN 978-960-6865-09-1. [18] Villi G., Pasut W., and Carli M., D., 2009, “Computational Aspects of Modeling Different Strategies For Kitchen Ventilation: A Comparison Between The Multi-Zone Approach And CFD Modeling With Reference To Predicted Indoor Pollutant Concentrations”, Eleventh International IBPSA Conference Glasgow, Scotland, July 27-30, - 1574. [19] Zhou, J. and Kim, C., 2010, “Numerical investigation of indoor CO2 concentration distribution in an apartment”, 3rd International Symposium on Sustainable Healthy Buildings; Seoul, Korea. 27 May. 133 [20] Mohammed, R., 2013, “Numerical Investigation of Indoor Air Quality and Thermal Comfort in a Ventilated Room”, World Academy of Science, Engineering and Technology International Journal of Environmental, Ecological, Geological and Marine Engineering Vol:7 No:12. [21] Brohard, G., Swierczyna, R., Sobiski, P., And Smith, V., Fisher, D., 2002, “Makeup Air Effects On Commercial Kitchen Exhaust System Performance” California Energy Commission, P500-03-007. [22] Pandey, M.R.,Neupane, R.P., Gautam,A., and Shrestha, I.B., 1989, “Domestic Smoke Pollution and Acute Respiratory Infections in a Rural Community of the Hill Region of Nepal”, Environment International, Vol. 15, pp. 337-340. [23] Albalak, R.,Frisancho, A.R., and Keeler, G.J., 1999, “Domestic Biomass Fuel Combustion and Chronic Bronchitis in Two Rural Bolivian Villages”, Thorax;54:1004–1008. [24] Zhang, J. and Smith, K. R., 1999, “Emissions of Carbonyl Compounds from Various Cook stoves in China”, Environmental Science and Technology, 33 (14), pp 2311–2320. [25] Ravi, M.R. ,Kohli, S. , and Ray, A., 2002, “Use of CFD Simulation as a Design Tool for Biomass Stoves”, Energy for Sustainable Development, Volume VI, No. 2. [26] Mishra, V., 2003, “Indoor air pollution from biomass combustionand acute respiratory illness in preschool age children in Zimbabwe”, International Journal of Epidemiology; 32:847–853, DOI: 10.1093/ije/dyg240. [27] Schei, M.A., Hessen, J.O., Smith, K.R., Bruce, N., McCracken, J., and Lopez, V., 2004, “Childhood Asthma and Indoor Woodsmoke from Cooking in Guatemala”, Journal of Exposure Analysis and Environmental Epidemiology 14, S110–S117. [28] Dasgupta, S., Huq, M., Khaliquzzaman, M., Pandey, K. and Wheeler D., 2006, “Indoor air quality for poor families: new evidence from Bangladesh” published in Indoor Air; 16: 426–444. [29] Smith, K. R., 2002, “Indoor air pollution in developing countries: recommendations for research” published in Indoor Air; 12: 198–207. 134 [30] Kilabuko, H., James, Matsuki, Hidieki, and Nakai, Satoshi, 2007, “Air Quality and Acute Respiratory Illness in Biomass Fuel using homes in Bagamoyo, Tanzania”, Int. J. Environ. Res. Public Health, 4(1), 39-44. [31] Kumar R.,Nagar J., Raj N., Kumar P., Kushwah A., Meena M. and Gaur S.N., 2008, “Impact of Domestic Air Pollution from Cooking Fuel on Respiratory Allergies in Children in India”, Asian Pacific Journal of Allergy and Immunology, 26: 213-222. [32] Padhi B. and Padhy P., Domestic Fuels, 2008, “Indoor Air Pollution, and Children’s Health, The Case of Rural India”, Annals of the New York Academy of Sciences, Volume 1140, Environmental Challenges in the Pacific Basin. [33] Gurley, E., Shohel M., Abdullah, S. and Luby, B. S., 2008, “Measuring The Health Effects of A Pilot Indoor Air Pollution Intervention In Bangladesh”, Draft protocol, ICDDR,B study team. [34] Kao, H. M., Chang, T.J., Hsieh, Y.F., Wang, C.H., and Hsieh. C.I., 2009, “Comparison of Airflow and Particulate Matter Transport in Multi-Room Buildings for Different Natural Ventilation Patterns”, Energy and Buildings 41, 966–974. [35] Kumie, A., Emmelin, A., Wahlberg, S., Berhane, Y., Ali, A., Mekonnen, E., Brandstrom, D., 2009, “Magnitude of indoor NO2 from biomass fuels in rural settings of Ethiopia”, published in Indoor Air; 19: 14–21. [36] Khalequzzaman, M., Kamijima, M., Sakai, K., Hoque, B. A. and Nakajim, T., 2010, “Indoor air pollution and the health of children in biomass- and fossil fuel users of Bangladesh situation in two different seasons” published in the Japanese Society for Hygiene. [37] Adefeso, I., Sonibare, J., Akeredolu, J., and Rabiu, J., 2012, “Environmental Impact of Portable Power Generator on Indoor Air Quality”, International Conference on Environment, Energy and Biotechnology IPCBEE vol.33. [38] Grabow, K., Still, D, and Bentson, S., 2013, “Test Kitchen Studies of Indoor Air Pollution from Biomass Cook Stoves”, Energy for Sustainable Development, Volume 17, Issue 5, Pages 458–462. 135 [39] Agarwall S. B., Sukhsohale N. D., Narlawar U. W., Phatak M. S., and Ughade S. N., 2013, “Effect Of Indoor Air Pollution During Cooking On Peak Expiratory Flow Rate And Its Association With Exposure Index In Rural Women”, Indian J Physiologic Pharmacology; 57(2) : 184–188. [40] Joshi, S., M., “The sick building syndrome”, Indian Journal of Occupational Environment and Medicine, 2008, 12(2), pp: 61–64. doi: 10.4103/0019- 5278.43262 [41] Kline, S. J. and McClintock, F. A., 1953, “Describing the uncertainties in single sample experiments”, Mechanical Engineering, pages 3–8. [42] Birch, K., Estimating Uncertainties in Testing, 2003, “An Intermediate Guide to Estimating and Reporting Uncertainty of Measurement in Testing”, British Measurement and Testing Association, March, Teddington, Middlesex, United Kingdom, TW110NQ. en_US
dc.identifier.uri http://hdl.handle.net/123456789/2272
dc.description Supervised by Prof. Dr. A.K.M. Sadrul Islam, Head, Mechanical and Chemical Engineering(MCE), Islamic University of Technology(IUT), Board Bazar, Gazipur-1704, Bangladesh, This thesis submitted to the Department of Mechanical and Chemical Engineering(MCE) in partial fulfillment of the requirements for the degree of Doctor of Philosophy (PhD) in MCE. en_US
dc.description.abstract Lack of proper ventilation of exhaust fumes from gas and biomass fired stoves in both urban and rural residential kitchens are a major health concern for majority populations. It could even cause destruction of property, reduced quality of life and lifespan. In this research, a typical urban kitchen with a standard dimension of 2.13m × 2.43m × 3.05m was modeled with single open door exit. Two heat sources were used to resemble the double burner gas stove of an urban residential kitchen. On the other hand, a single burner traditional soil stove was used for the model of a rural kitchen with dimension of 3.50 m × 2.20 m × 1.85 m. In both cases, steady state simulations were performed using a three dimensional CFD code with appropriate boundary conditions. The present numerical method for urban kitchen was validated by comparing with the experimental data and showed very reasonable agreement. A grid independence test was also performed to determine the optimum grid resolution reflecting the accuracy of the numerical solution. For urban kitchen, the results are presented for temperature field and velocity field, and CO2 concentration and discussed under both natural forced ventilation systems. For the gas stoves located in the kitchen corner, the flow tends to shift towards the corner side wall and exhibits high temperature zone all above the burners. A comparative analysis between the ventilation (natural and forced) and no ventilation conditions are reported. Very high concentration (above 5000 PPM) of carbon dioxide gas was observed at the plane passing the breathing zone. Exposure to this environment for longer time may cause serious health damage of the occupants. A kitchen hood system has been simulated for both thermal comfort and carbon dioxide gas emission for the kitchen. It has been observed that the carbon dioxide gas concentration significantly reduced within the breathing zone due to use of kitchen hood system. In the breathing zone, the CO2 concentration is only about 500 PPM which is 10 times lower than the close vent case. Two other positions of the kitchen hood suction have been studied for the effect of thermal distribution and emission rate. It has been observed that both front and base extraction method 19 reduces the emissions significantly to well below the safe limit. They also can maintain thermal comfort quite well inside the kitchen space. For the rural kitchen study, varying intensity of emissions of CO, CO2 and Particulate Matter (PM) from different kinds of Bio-fuels burning have been investigated. Dispersions of these pollutants in the kitchen space have been investigated for without ventilation and natural ventilation without hood and with hood systems. It has been observed that at unventilated condition, CO, CO2 and PM concentration exceeds safe standard value. Even the natural ventilation condition fails to keep the concentration below the safe limit. However, a significant improvement can be observed for the kitchen with hood under natural ventilation. en_US
dc.language.iso en en_US
dc.publisher Department of Mechanical and Production Engineering(MPE), Islamic University of Technology(IUT), Board Bazar, Gazipur-1704, Bangladesh en_US
dc.title Numerical Study of Emission Control of Urban and Rural Kitchens for Healthy Environment en_US
dc.type Thesis en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search IUT Repository


Advanced Search

Browse

My Account

Statistics