Error Analysis of Elasticity Imaging Technique Based on Number, Size and Location of Tumors for Making Robust Modulus Reconstruction Process

Show simple item record

dc.contributor.author Kamal, Abu Hena Md. Mustafa
dc.date.accessioned 2020-10-14T17:20:20Z
dc.date.available 2020-10-14T17:20:20Z
dc.date.issued 2018-11-15
dc.identifier.citation [1] M. Li, Statistical analysis of a three-dimensional axial strain and axial-shear strain elastography algorithm. [College Station, Tex.]: [Texas A & M University], 2012. [2] A. Itoh, E. Ueno, E. Tohno, H. Kamma, H. Takahashi, T. Shiina, M. Yamakawa and T. Matsumura, "Breast Disease: Clinical Application of US Elastography for Diagnosis", Radiology, vol. 239, no. 2, pp. 341-350, 2006. [3] C. de Korte, E. Cespedes, A. van der Steen, G. Pasterkamp and N. Bom, "Intravascular ultrasound elastography: assessment and imaging of elastic properties of diseased arteries and vulnerable plaque", European Journal of Ultrasound, vol. 7, no. 3, pp. 219-224, 1998. [4] D. Franklin, W. Schlegel and R. Rushmer, "Blood Flow Measured by Doppler Frequency Shift of Back-Scattered Ultrasound", Science, vol. 134, no. 3478, pp. 564-565, 1961. [5] D. Baker, "Pulsed ultrasonic Doppler blood-flow sensing", IEEE Transactions on Sonics and Ultrasonics, vol. 17, no. 3, pp. 170-184, 1970. [6] C. Kasai, K. Namekawa, A. Koyano, and R. Omoto, "Real-time two-dimensional blood flow imaging using an autocorrelation technique", IEEE Transactions on Sonics and Ultrasonics, vol. 32, no. 3, pp. 458-464, 1985. [7] T. L. Szabo, Diagnostic Ultrasound Imaging: Inside Out. Elsevier Academic Press, 2004. [8] T. Hall, Y. Zhu, and C. Spalding, “In vivo real-time freehand palpation imaging”, Ultrasound in Medicine and Biology, vol. 29, no. 3, pp. 427-435, 2003. [9] J. Lindop, G. Treece, A. Gee, and R. Prager, “3D elastography using freehand ultrasound”, Ultrasound in Medicine and Biology, vol. 32, no. 4, pp. 529-545, 2006. [10] A. Pesavento, C. Perrey, M. Krueger, and H. Ermert, “A time efficient and accurate strain estimation concept for ultrasonic elastography using iterative phase zero estimation”, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, vol. 46, no. 5, pp. 1057- 1067, 1999. [11] T. Varghese and J. Ophir, “A theoretical framework for performance characterization of elastography: the strain filter”, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, vol. 44, no. 1, pp. 164-172, 1997. [12] P. Barbone and J. Bamber, “Quantitative elasticity imaging: what can and cannot be inferred from strain images”, Physics in Medicine and Biology, vol. 47, no. 12, pp. 2147– 2164, 2002. [13] K. Raghavan and A. Yagle, “Forward and inverse problems in elasticity imaging of soft tissues”, IEEE Transactions on Nuclear Science, vol. 41, no. 4, pp. 1639–1648, 1994. [14] A. Skovoroda, S. Emelianov, and M. O‟Donnell, “Tissue elasticity reconstruction based on ultrasonic displacement and strain images”, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, vol. 42, no. 4, pp. 747–765, 1995. [15] F. Kallel and M. Bertrand, “Tissue elasticity reconstruction using linear perturbation method”, IEEE Transactions on Medical Imaging, vol. 15, no. 3, pp. 299–313, 1996. [16] C. Sumi and K. Nakayama, “A robust numerical solution to reconstruct a globally relative shear modulus distribution from strain measurements”, IEEE Transactions on Medical Imaging, vol. 17, no. 3, pp. 419–428, 1998. [17] M. Doyley, P. Meaney and J. Bamber, “Evaluation of an iterative reconstruction method for quantitative elastography”, Physics in Medicine and Biology, vol. 45, no. 6, pp. 1521–1540, 2000. [18] S. Aglyamov, A. Skovoroda, H. Xie, K. Kim, J. Rubin, M. O'Donnell, T. Wakefield, D. Myers and S. Emelianov, "Model-Based Reconstructive Elasticity Imaging Using Ultrasound", International Journal of Biomedical Imaging, pp. 1-11, 2007. [19] H. Ponnekanti, J. Ophir, Y. Huang, and I. C´espedes, “Fundamental mechanical limitations on visualization of elasticity contrast in elastography”, Ultrasound in Medicine and Biology, vol. 21, no. 4, pp. 533–543, 1995. [20] B. Garra, I. C´espedes, J. Ophir, S. Spratt, R. Zuurbier, C. Magnant, and M. Pennanen, “Elastography of breast lesions: initial clinical results”, Radiology, vol. 202, no. 1, pp. 79–86, 1997. [21] T. Hall, Y. Zhu, and C. Spalding, “In vivo real-time freehand palpation imaging”, Ultrasound in Medicine and Biology, vol. 29, no. 3, pp. 427–435, 2003. [22] T. Matsumura, S. Tamano, S. Shinomura, T. Mitake, M. Yamakawa, T. Shiina, A. Itoh, and E. Ueno, “Diagnostic results for breast disease by real-time elasticity imaging system”, In Proceedings of IEEE Ultrasonics Symposium, pp. 1484–1487, 2004. [23] A. Itoh, E. Ueno, E. Tohno, H. Kamma, H. Takahashi, T. Shiina, M. Yamakawa, and T. Matsumura, “Breast disease: clinical application of US elastography for diagnosis”, Radiology, vol. 239, no. 2, pp. 341–350, 2006. [24] D. Regner, G. Hesley, N. Hangiandreou, M. Morton, M. Nordland, D. Meixner, T. Hall, M. Farrell, J. Mandrekar, W. Harmsen, and J. Charboneau, “Breast lesions: evaluation with US strain imaging - clinical experience of multiple observers”, Radiology, vol. 238, no. 2, pp. 425– 437, 2006. [25] W. Svensson and D. Amiras, “Ultrasound elasticity imaging”, Breast Cancer Online, vol. 9, no. 6, pp. 1–7, 2006. [26] R. Barr, “Clinical applications of a real time elastography technique in breast imaging”, Ultrasonic Measurement and Imaging of Tissue Elasticity, pp. 112, 2006. [27] A. Pesavento and A. Lorenz, “Real time strain imaging - a new ultrasonic method for cancer detection: first study results”, In Proceedings of IEEE Ultrasonics Symposium, pp. 1647–1652, 2001. [28] N. Miyanaga, H. Akaza, M. Yamakawa, T. Oikawa, N. Sekido, S. Hinotsu, K. Kawai, T. Shimazui, and T. Shiina, “Tissue elasticity imaging for diagnosis of prostate cancer: a preliminary report”, International Journal of Urology, vol. 13, no. 12, pp. 1514–1518, 2006. [29] M. Biot, "General Theory of Three‐Dimensional Consolidation", Journal of Applied Physics, vol. 12, no. 2, pp. 155-164, 1941. [30] M. Biot, “Mechanics of deformation and acoustic propagation in porous media”, Journal of Applied Physics, vol. 33, no. 2, pp. 1482-1498, 1962. [31] A. Green and J. Adkins, Large elastic deformations. Oxford: Clarendon Press, 1970. [32] R. Ogden, Non-linear Elastic Deformations. Mineola, NY: Dover Publications Inc., 1997. [33] A. Skovoroda and A. Sarvazyan, “Determination of viscoelastic shear characteristics of a medium from its response to focused ultrasonic loading”, Biophysics, vol. 44, no. 2, pp. 325-329, 1999. [34] A. Skovoroda, The Problems of Theory of Elasticity for Diagnosing Pathology of Soft Biological Tissues. Moscow: Fizmatlit, 2006. [35] G. Smith, Numerical Solution of Partial Differential Equations: Finite Difference Methods, Third ed. Oxford: University Press, 1985. [36] J. Fowlkes, S. Emelianov and J. Pipe, “Magnetic-resonance imaging techniques for detection of elasticity variation”, vol. 22, no. 2, pp. 1771-1778, 1995. [37] E. Van Houten, J. Weaver, M. Miga, F. Kennedy and K. Paulsen, "Elasticity reconstruction from experimental MR displacement data: initial experience with an overlapping subzone finite element inversion process", Medical Physics, vol. 27, no. 1, pp. 101-107, 2000. [38] P. Barbone and J. Bamber, "Quantitative elasticity imaging: what can and cannot be inferred from strain images", Physics in Medicine and Biology, vol. 47, no. 12, pp. 2147-2164, 2002. [39] G. Christensen, M. Sonka, J. Kybic and D. Smutek, “Computational elastography from standard ultrasound image sequences by global trust region optimization”, Medical Imaging, vol. 356, no. 5, pp. 299-310, 2005. [40] E. Park and A. Maniatty, "Shear modulus reconstruction in dynamic elastography: time harmonic case", Physics in Medicine and Biology, vol. 51, no. 15, pp. 3697-3721, 2006. [41] W. Khaled, S. Reichling, O. Bruhns and H. Ermert, "Ultrasonic strain imaging and reconstructive elastography for biological tissue", Ultrasonics, vol. 44, pp. 199-202, 2006. [42] J. Luo, K. Ying and J. Bai, “Elasticity reconstruction for ultrasound elastography using a radial compression: An inverse approach”, Ultrasonics, vol. 44, pp. 195-198, 2006. [43] P. Barbone and A. Oberai, "Elastic modulus imaging: some exact solutions of the compressible elastography inverse problem", Physics in Medicine and Biology, vol. 52, no. 6, pp. 1577-1593, 2007. [44] M. Richards, P. Barbone and A. Oberai, "Quantitative three-dimensional elasticity imaging from quasi-static deformation: a phantom study", Physics in Medicine and Biology, vol. 54, no. 3, pp. 757-779, 2009. [45] T. Hall, A. Oberait and P. Barbone, "Elastic nonlinearity imaging," in Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Minneapolis, MN, 2009, pp. 1967-1970. [46] F. Kallel and M. Bertrand, "Tissue elasticity reconstruction using linear perturbation method", IEEE Transactions on Medical Imaging, vol. 15, no. 3, pp. 299-313, 1996. [47] Chikayoshi Sumi and K. Nakayama, "A robust numerical solution to reconstruct a globally relative shear modulus distribution from strain measurements", IEEE Transactions on Medical Imaging, vol. 17, no. 3, pp. 419-428, 1998. [48] H. Kwon, B. Shin, D. Gopaul and S. Fienberg, "Strain ratio vs. modulus ratio for the diagnosis of breast cancer using elastography", Biomedical Engineering Letters, vol. 4, no. 3, pp. 292-300, 2014. [49] T. Chenevert, A. Skovoroda, M. O′donnell and S. Emelianov, "Elasticity reconstructive imaging by means of stimulated echo MRI", Magnetic Resonance in Medicine, vol. 39, no. 3, pp. 482-490, 1998. [50] M. Lubinski, S. Emelianov and M. O'Donnell, "Speckle tracking methods for ultrasonic elasticity imaging using short-time correlation", IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, vol. 46, no. 1, pp. 82-96, 1999. [51] S. Aglyamov, A. Skovoroda, J. Rubin, M. O'Donnell and S. Emelianov, "Model-based reconstructive elasticity imaging of deep venous thrombosis", IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, vol. 51, no. 5, pp. 521-531, 2004. [52] P. Bharti, D. Mittal and R. Ananthasivan, "Preliminary Study of Chronic Liver Classification on Ultrasound Images Using an Ensemble Model", Ultrasonic Imaging, vol. 23, no. 5, pp. 234-244, 2018. [53] F. Mortazavi, M. Lévesque and I. Villemure, "Image-based Continuous Displacement Measurements Using an Improved Spectral Approach", Strain, vol. 49, no. 3, pp. 233-248, 2013. [54] J. Mayrose, "A Noninvasive System for Biomechanical Properties Measurement of Soft Tissue", Journal of Medical Devices, vol. 2, no. 3, p. 031005, 2008. [55] S. Hsu, "Acoustic Radiation Force and Elasticity Imaging", Journal of Medical Ultrasound, vol. 24, no. 1, pp. 1-2, 2016. [56] Y. Yamakoshi, J. Sato and T. Sato, "Ultrasonic imaging of internal vibration of soft tissue under forced vibration", IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, vol. 37, no. 2, pp. 45-53, 1990. [57] K. Kennedy, L. Chin, R. McLaughlin, B. Latham, C. Saunders, D. Sampson and B. Kennedy, "Quantitative micro-elastography: imaging of tissue elasticity using compression optical coherence elastography", Scientific Reports, vol. 5, no. 1, 2015. [58] K. Nightingale, M. Palmeri, R. Nightingale and G. Trahey, "On the feasibility of remote palpation using acoustic radiation force", The Journal of the Acoustical Society of America, vol. 110, no. 1, pp. 625-634, 2001. [59] S. Mousavi, H. Rivaz, A. Sadeghi-Naini, G. Czarnota and A. Samani, "Breast Ultrasound Elastography Using Full Inversion-Based Elastic Modulus Reconstruction", IEEE Transactions on Computational Imaging, vol. 3, no. 4, pp. 774-782, 2017. [60] M. Urban, Shigao Chen and J. Greenleaf, "Error in estimates of tissue material properties from shear wave dispersion ultrasound vibrometry", IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, vol. 56, no. 4, pp. 748-758, 2009. [61] T. Shiina and M. Yamakawa, "Fast reconstruction of tissue elastic modulus image by ultrasound", in Engineering in Medicine and Biology 27th Annual Conference, Shanghai, China, 2005. [62] X. Pan, K. Liu, J. Bai and J. Luo, "A regularization-free elasticity reconstruction method for ultrasound elastography with freehand scan", BioMedical Engineering OnLine, vol. 13, no. 1, p. 132, 2014. en_US
dc.identifier.uri http://hdl.handle.net/123456789/524
dc.description Supervised by Prof. Dr. Golam Sarowar en_US
dc.description.abstract The principal objective of the present work is to understand the elasticity imaging complexity and the probability of noise to measure Young‟s modulus based on number, size and location of tumors. This study is to make the modulus reconstruction process robust. For numerical computation, a model of breast tissue with tumor inclusion is created using a finite element method based modeling software called COMSOL Multiphysics. Fat and skin are placed to make the model more realistic. This is a 2-dimensional model. 3cm by 3.6cm area of soft tissue is modeled first. Tumor of fixed radius is included then. The Young‟s modulus values for fat, skin, soft tissue and hard tumors are set according to literature. More models are designed for different number, size and location of tumors. These models are used for error analysis of elasticity imaging technique. For elasticity imaging it is necessary to press a probe on the top surface which is implemented by fixed displacement in our model. Displacement is set according to literatures. Values of stress and strain of 27462 points of the model are exported from Comsol Multiphysics to Matlab for calculation of Young‟s Modulus. A matrix of 361 by 301 is made with interpolated values in Matlab for further calculation. Percentage error is calculated for seven sections of the model (one inside tumor, six outside tumor). It is found that error is less near to the upper surface, error increases with increment in depth. Error is less inside tumor comparing to outside tumor. Maximum error is 188.48 at lower side and minimum value is 13.3 at Inside tumor. For various tumor sizes, error increases with increase of tumor size. But inside tumor error decreases with increase of tumor size. For double tumors it is found that error is reduced near to the small tumor. when the small tumor is at top lower side error is 77.62% but when the smaller tumor is at bottom the error is less and it decreases to a value of 58.68%. There is not much effect for variation of displacement field rather than 0.03 cm for tumor at middle of the tissue model. So, the numerical simulation can be viably used to develop a mathematical error pattern which can help understand the elasticity imaging complexity and the probability of noise to measure Young‟s modulus and hence can improve efficiency of modulus reconstruction process. en_US
dc.language.iso en en_US
dc.publisher Department of Electrical and Electronic Engineering, Islamic University of Technology, Board Bazar, Gazipur, Bangladesh en_US
dc.title Error Analysis of Elasticity Imaging Technique Based on Number, Size and Location of Tumors for Making Robust Modulus Reconstruction Process en_US
dc.type Thesis en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search IUT Repository


Advanced Search

Browse

My Account

Statistics