3d Numerical Analysis of The Effect of Various Geometric Parameters of Eathes Under Steady Operating Conditions

Show simple item record

dc.contributor.author Hero, Md. Kabbir Hossain
dc.contributor.author Moin, Md. Emran Hossain
dc.date.accessioned 2020-10-28T17:28:20Z
dc.date.available 2020-10-28T17:28:20Z
dc.date.issued 2018-11-15
dc.identifier.citation [1] A.M. Omer, Energy, environment and sustainable development, Renew. Sustain. Energy Rev. 12 (2008) 2265–2300. doi:10.1016/j.rser.2007.05.001. [2] P. Nejat, F. Jomehzadeh, M.M. Taheri, M. Gohari, M.Z. Abd Majid, A global review of energy consumption, CO2 emissions and policy in the residential sector (with an overview of the top ten CO2 emitting countries), Renew. Sustain. Energy Rev. 43 (2015) 843–862. doi:10.1016/j.rser.2014.11.066. [3] Jacovides C, Mihalakakou G, Santamouris M, Lewis J. On the ground temperature profile for passive cooling applications in buildings. Sol Energy 1996;57(3):167–75. [4] Mihalakakou G, Santamouris M, Asimakopoulos D. Modelling the thermal performance of earth-to-air heat exchangers. Sol Energy 1994;53(3):301–5. [5] Sawhney R, Buddhi D, Thanu N. An experimental study of summer performance of a recirculation type underground air pipe air conditioning system. Build Environ 1999;34:189–96 [6] Vaz J, Sattler MA, dos Santos ED, Isoldi LA. Experimental and numerical analysis of an earth air heat exchanger. Energy Build 2011;43(9):2476–82. http:// dx.doi.org/10.1016/j.enbuild.2011.06.003, URL 〈http://www.sciencedirect.com/ science/article/pii/S0378778811002519〉. [7] Jayashankar BC, Sawhney RL, Sodha MS. Effect of different surface treatments of the surrounding earth on thermal performance of earth-integrated buildings. Int J Energy Res 1989;13:605–19. [8] Givoni B, Katz L. Earth temperatures and underground buildings. Energy Build 1985;8(1):15–25. http://dx.doi.org/10.1016/0378-7788(85)90011-8, URL 〈http://www.sciencedirect.com/science/article/pii/0378778885900118〉. [9] Omer AM. Ground-source heat pumps systems and applications. Renew Sustain Energy Rev 2008;12(2):344–71. http://dx.doi.org/10.1016/j.rser.2006.10.003, 〈http://www.sciencedirect.com/science/article/pii/S1364032106001249〉. [10] Esen H, Inalli M, Esen M. Numerical and experimental analysis of a horizontal ground-coupled heat pump system. Build Environ 2007;42(3):1126–34. http:// dx.doi.org/10.1016/j.buildenv.2005.11.027,〈http://www.sciencedirect.com/science/article/pii/S03 60132305005068〉. [11] Givoni B. Earth-integrated buildings, an overview. Archit Sci Rev 1981;24(2):42–53, 〈http://dx.doi.org/10.1080/00038628.1981.9696465〉. [12] Deshmukh MK, Sodha MS, Sawhney RL. Effect of depth of sinking on thermal performance of partially underground building. Int J Energy Res 1991;15(5):391–403, 〈http://dx.doi.org/10.1002/er.4440150506〉. [13] Esen H, Esen M, Ozsolak O. Modelling and experimental performance analysis of solar-assisted ground source heat pump system. J Exp Theor Artif Intell 2017;29(1):1–17, 〈http://dx.doi.org/10.1080/0952813X.2015.1056242〉. [14] Lucia U, Simonetti M, Chiesa G, Grisolia G. Ground-source pump system for heating and cooling: review and thermodynamic approach. Renew Sustain Energy Rev 2017; 70:867–74. http://dx.doi.org/10.1016/j.rser.2016.11.268 〈http://www.sciencedirect.com/science/article/pii/S1364032116310504〉. [15] nall M, Esen H. Experimental thermal performance evaluation of a horizontal ground-source heat pump system. Appl Therm Eng 2004;24(1415):2219–32. http://dx.doi.org/10.1016/j.applthermaleng.2004.01.005, http://www.sciencedirect.com/science/article/pii/S1359431104000341. [16] Wu W, You T, Wang B, Shi W, Li X. Simulation of a combined heating, cooling and domestic hot water system based on ground source absorption heat pump. Appl Energy 2014; 126:113–22. http://dx.doi.org/10.1016/j.apenergy.2014.04.006, URL 〈http://www.sciencedirect.com/science/article/pii/S0306261914003390〉. [17] Balbay A, Esen M. Experimental investigation of using ground source heat pump system for snow melting on pavements and bridge decks. Sci Res Essays 2010;5(24):3955–66. [18] Balbay A, Esen M. Temperature distributions in pavement and bridge slabs heated by using vertical ground-source heat pump systems. Acta Sci-Technol 2013;35(4):677–85. [19] Esen H, Inalli M, Esen M. A techno-economic comparison of ground-coupled and air-coupled heat pump system for space cooling. Build Environ 2007;42(5):1955–65. http://dx.doi.org/10.1016/j.buildenv.2006.04.007, http://www.sciencedirect.com/science/article/pii/S0360132306000977. [20] Khatry AK, Sodha MS, Malik MAS. Periodic variation of ground temperature with depth. Sol Energy 1978; 20:425–7. [21] Wu H, Wang S, Zhu D. Modelling and evaluation of cooling capacity of earthairpipe systems. Energy Convers Manag 2007; 48:1462–71. [22] Bansal NK, Sodha MS, Bhardwaj SS. Performance of earth–air tunnel system. Energy Research 1983;7(4):333–41. [23] Bharadwaj SS, Bansal NK. Temperature distribution inside ground for various surface conditions. Building and Environment 1983;16(3):183–92. [24] Santamouris M, Argiriou A, Vallindras M. Design and operation of a low energy consumption passive solar agricultural greenhouse. Solar Energy 1994;52(5):43–9. [25] Ozgener L. A review on the experimental and analytical analysis of earth to air heat exchanger (eahe) systems in turkey. Renew Sustain Energy Rev 2011; 15:4483–90. [26] Trilok Singh Bisoniya PB, Kumar Anil. Experimental and analytical studies of earthair heat exchanger (eahe) systems in india: a review. Renew Sustain Energy Rev 2013; 19:238–46. [27] Clara Peretti MDCRZ, Zarrella Angelo. The design and environmental evaluation of earth-to-air heat exchangers(eahe). A literature review. Renew Sustain Energy Rev 2013; 28:107–16. [28] Kaushal M. Geothermal cooling/heating using ground heat exchanger for various experimental and analytical studies: comprehensive review. Energy Build 2017; 139:634–52. http://dx.doi.org/10.1016/j.enbuild.2017.01.024, URL 〈http://www.sciencedirect.com/science/article/pii/S0378778817300750〉. [29] R. Kumar, S.C. Kaushik, S.N. Garg, Heating and cooling potential of an earth-to-air heat exchanger using artificial neural network, Renewable Energy, 31 (2006) 1139–1155 [30] C.P. Jacovides, G. Mihalakakou, M. Santamouris, J.O. Lewis, On the ground temperature profile for passive cooling applications in buildings, Solar Energy, 57 (1996) 167–175. [31] V.M. Puri, Heat and mass transfer analysis and modelling in unsaturated ground soils for buried tube systems, Energy in Agriculture Engineering, 6 (1987) 179–183. [32] M. Bojic, G. Papadakisb, S. Kyritsisb, Energy from a two-pipe, earth-to-air heat exchanger, Energy, 24 (1999) 519–523. [33] M. Krarti, J.F. Kreider, Analytical model for heat transfer in an underground air tunnel, Energy Conservation and Management, 37 (1996) 1561-1574. [34] D. Deglin, L.V. Caenegem, P. Dehon, Subsoil heat exchangers for the air conditioning of livestock buildings, Journal of Agriculture Engineering, 73 (1999) 179–188. [35] S. Thiers, B. Peuportier, Thermal and environmental assessment of a passive building equipped with an earth-to-air heat exchanger in France, Solar Energy, 82 (2008) 820–831. [36] V. Bansal, R. Misra, G. D. Agrawal, J. Mathur, Performance analysis of earth-pipe-air heat exchanger for winter heating, Energy and Buildings (2009) [37] V. Bansal, R. Misra, G. D. Agrawal, J. Mathur, Performance analysis of earth-pipe-air heat exchanger for summer cooling, Energy and Buildings (2010) [38] V. Bansal, R. Misra, G. D. Agarwal, J. Mathur, ‘Derating Factor’ new concept for evaluating thermal performance of earth air tunnel heat exchanger: A transient CFD analysis, [39] V. Bansal, R. Misra, G. D. Agarwal, J. Mathur, Transient effect of soil thermal conductivity and duration of operation on performance of Earth Air Tunnel Heat Exchanger, Energy and Buildings (2013) [40] A. Yildiz, O. Ozgener, L. Ozgener, Exergetic performance assessment of photo voltaic cell (PV) assisted earth to air heat exchanger (EAHE) system for solar greenhouse cooling, Energy and Buildings (2010). [41] R. Misra, V. Bansal, G.D. Agarwal, J. Mathur, T. Aseri, Transient analysis based determination of derating factor for Earth Air Tunnel Heat Exchanger in winter. [42] R. Misra, V. Bansal, G.D. Agarwal, J. Mathur, CFD analysis based parametric study of derating factor for Earth Air Tunnel Heat Exchanger. [43] R. Misra, V. Bansal, G.D. Agarwal, J. Mathur, T. Aseri, Transient analysis based determination of derating factor for Earth Air Tunnel Heat Exchanger in winter, Energy and Buildings (2013). [44] H. Li, Y. Yu, F. Niu, M. Shafik, B.Chen, Performance of a coupled cooling system with earth- to- air heat exchanger and soalr chimney, Renewable Energy (2014). [45] F. Al-Ajmi, D.L. Loveday, V.I. Hanby, The cooling potential of earth-air heat exchangers for domestic buildings in a desert climate, Building and Environment (2006). [46] H. Wu, S. Wang, D. Zhu, Modelling and evaluation of cooling capacity of earth–air–pipe systems. [47] A. Mathur, A. Srivastava, J. Mathur, S. Mathur, G.D. Agarwal, Transient effect of soil thermal diffusivity on performance of EATHE system. [48] A. Mathur, Piyam, S. Mathur, G.D. Agarwal, J. Mathur, Comparative study of straight and spiral Earth Air Tunnel Heat Exchanger system operated in cooling and heating modes. [49] R. Misra, T.K. Aseri, V. Bansal, CFD ANALYSIS OF THERMAL INFLUENCE ZONE OF EARTH AIR TUNNEL HEAT EXCHANGER UNDER TRANSIENT CONDITIONS [50] A. de J. Freire, J. Luís, C. Alexandre, V.B. Silva, N.D. Couto, A. Rouboa, Compact buried pipes system analysis for indoor air conditioning. [51] V.P. Kabashnikov, L.N. Danilevskii, V.P. Nekrasov, I.P. Vityaz, Analytical and numerical investigation of the characteristics of a soil heat exchanger for ventilation systems. [52] M.S. Sodha, U. Mai-Iajan, R.L. SAWHNEY, THERMAL PERFORMANCE OF A PARALLEL EARTH AIR-PIPES SYSTEM. [53] A. Mathur, A. Kumar, Surana, P. Verma, S. Mathur, G.D. Agarwal, J. Mathur, Investigation of soil thermal saturation and recovery under intermittent and continuous operation of EATHE. [54] A. Mathur, A. Kumar, Surana, S. Mathur, Numerical investigation of the performance and soil temperature recovery of an EATHE system under intermittent operations. [55] A. Mathur, A. Srivastava, G.D. Agarwal, S. Mathur, J. Mathur, CFD analysis of EATHE system under transient conditions for intermittent operation. [56] ANSYS, 2015 [online] http://www.ansys.com/en in” http://www.ansys.com/en in. [57] J.D. Anderson, et al., in: J.F. Wendt (Ed.), Computational Fluid Dynamics An Introduction, Springer, Berlin, Germany, 2009. [58] F.X. Niu, L. Ni, Y. Yang, Thermal accumulation effect of ground-coupled heat pump system, in: International Conference on Electric Technology and Civil Engineering (ICETCE), 2011, pp. 1805–1807. [59] Dhaliwal AS, Goswami DY. Heat transfer analysis in environmental control using an underground air tunnel. J Solar Energy Eng 1985;107:141–5 en_US
dc.identifier.uri http://hdl.handle.net/123456789/623
dc.description Supervised by Dr. Arafat Ahmed Bhuiyan en_US
dc.description.abstract Space heating and cooling is a comfort requirement which results in a significant amount of energy consumption. EATHE (Earth Air Thermal Heat Exchanger) is one of the passive ways of space heating and cooling that can reduce the energy consumption notably. In this paper, the effect of different geometric parameters; cross section of the pipe, inclusion of fins on the pipe, pitch of multiple pipe arrangements on the thermal performance of EATHEs under steady and transient conditions were analyzed. Since, the performance deteriorates over the continuous operation of the EATHEs, their performance under periodic operations were studied. A validated three- dimensional, transient numerical model was used to carry out the analysis. The governing equations, based on the k–Ɛ model and energy equation were used to describe the turbulence and heat transfer phenomena. The results are compared in terms of the outlet temperature of air and heat transfer rate. en_US
dc.language.iso en en_US
dc.publisher Department of Mechanical and Production Engineering, Islamic University of Technology, Board Bazar, Gazipur, Bangladesh en_US
dc.title 3d Numerical Analysis of The Effect of Various Geometric Parameters of Eathes Under Steady Operating Conditions en_US
dc.type Thesis en_US