Optimizing the length of Earth Air Tunnel Heat Exchanger based on CFD analysis

Show simple item record

dc.contributor.author Mahmud, Saikot
dc.contributor.author Hamid, Sami
dc.date.accessioned 2020-11-01T13:56:21Z
dc.date.available 2020-11-01T13:56:21Z
dc.date.issued 2018-11-15
dc.identifier.citation [1] Bansal Vikas, Misra Rohit, Agrawal Ghanshyam Das, Mathur Jyotirmay. Performance analysis of earth–pipe air heat exchanger for winter heating. Energy and Buildings 2009;41:1151–4. [2] Bansal Vikas, Misra Rohit, Agrawal Ghanshyam Das, Mathur Jyotirmay. Performance analysis of earth–pipe air heat exchanger for summer cooling. Energy and Buildings 2010;42:645–8. [3] Bansal NK, Sodha MS, Bhardwaj SS. Performance of earth–air tunnel system. Energy Research 1983;7(4):333–41. [4] Bharadwaj SS, Bansal NK. Temperature distribution inside ground for various surface conditions. Building and Environment 1983;16(3):183–92. [5] Santamouris M, Argiriou A, Vallindras M. Design and operation of a low energy consumption passive solar agricultural greenhouse. Solar Energy 1994;52(5):43–9. [6] Kumar Rakesh, Kaushik SC, Garg SN. Heating and cooling potential of an earth-to-air heat exchanger using artificial neural network. Renewable Energy 2006;31:1139–55. [7] Sodha MS, Sharma AK, Singh SP, Bansal NK, Kumar A. Evaluation of an earth– air–tunnel system for cooling/heating of a hospital complex. Building and Environment 1984;20(2):115–22. [8] Milun Stanko, Klic Tomislav, Bego Ozren. Measurment of soil thermal properties by spherical probe. IEEE transactions on instrumentation and measurement 2005;54 (3). [9] Kersten MS Laboratory research for the determination of the thermal properties of soils, Bulletin No. 28. Minneapolis, MN: Engineering Experiment Station, University of Minnesota; 1949. [10] de Vries DA. Thermal properties of soils. In: van Wijk WR, editor. Physics of plant environment. Amsterdam: North-Holland Publishing Company; 1963. [11] de Vries DA. Heat transfer in soils. In: de Vries DA, Afgan NH, editors. Heat and mass transfer in the biosphere. Washington, DC: Scripta Book Co.; 1975. p. 5–28. [12] Hillel D. Introduction to soil physics. San Diego, CA: Academic Press; 1982. [13] Nofziger DL Soil temperature changes with time and depth: theory. /http:// soilphysics.okstate.edu/software/SoilTemperature/document.pdfS. [14] Becker BR, Misra A, Fricke BA. Development of correlations for soil thermal conductivity. International Communications in Heat and Mass Transfer 1992;19:59–68. [15] Chen Y, Shi M, Li X. Experimental investigation on heat moisture and salt transfer in soil. International Communications in Heat and Mass Transfer 2006;33(9):1122–9. [16] Yu ZMX, Peng F, Li XD, Fang ZH. A simplified model for measuring thermal properties of deep ground soil. Experimental Heat Transfer 2004;17:119–30. [17] Ozgener Leyla. A review on the experimental and analytical analysis of earth to air heat exchanger (EAHE) systems in Turkey. Renewable and Sustainable Energy Reviews 2011;15(9):4483–90. [18] Scott NR, Parsons RA, Kochler TA. Analysis and performance of an earth–air heat exchanger, ASAE Paper No. 65–840 (1965). [19] Goswami DY, Ileslamlou S. Performance analysis of a closed loop climate control system using underground air tunnel. Solar Energy Engineering 1990;112:76–81. [20] Lund J, Sanner B, Rybach L, Curtis G, Hellstro€m G. Geothermal (ground-source) heat pumps—a world overview, GHC Bulletin, September, 2004. [21] Sanner B. Current status of ground source heat pumps in Europe, Futurstock, Warsaw, 2003. [22] Hubner H, Hermelink A. Mieter im passivhaus-nutzungsorientierte gestal- ¨ tung als voraussetzung funachhaltiges wohnen. In: Schrader U, Hansen U, ¨ editors. Nachhaltiger Konsum. Frankfurt, Germany: Campus Forschung; 2001. p. 137–48 [in German]. [23] Badescu V. Economic aspects of using ground thermal energy for passive house heating. Renewable Energy 2007;32:895–903. [24] Pfafferott Jens. Evaluation of earth-to-air heat exchangers with a standardised method to calculate energy efficiency. Energy and Buildings 2003;35:971–83. [25] D’Accadia MD, de Rossi F. Thermo-economic optimization of a refrigeration plant. International Journal of Refrigeration 1998;21(1):42–54. [26] Tzaferis A, LIParakis D, Santamouris M, Argiriou A. Analysis of the accuracy and sensitivity of eight models to predict the performance of earth to air heat exchanger. Energy and Buildings 1992;18:35–43. [27] Mihalakakou G, Santamouris M, Asimakopoutos D. Modeling the thermal performance of the earth to air heat exchanger. Solar Energy 1994;53(3): 301–5. [28] Bojic M, Trifunovic N, Papadakis G, Kyritsis S. Numerical simulation, technical and economic evolution of air to earth heat exchanger coupled to building. Energy 1997;22(12):1151–8. [29] Gauthier C, Lacroix M, Bernier H. Numerical simulation of soil heat exchanger storage system for greenhouse. Solar Energy 1997;60(6):333–46. [30] Hollmiller P, Lachal B. Cooling and preheating with buried pipe systems: monitoring, simulation and economic aspects. Energy and Building 2001;33(5): 509–18. [31] Wu H, Wang S, Zhu D. Modeling and evaluation of cooling capacity of earth– air–pipe systems. Energy Conversion and Management 2007;48:1462–71. [32] Aslam Bhutta Muhammad Mahmood, Hayat Nasir, Hassan Bashir Muhammad, Rais Khan Ahmer, Naveed Ahmad Kanwar, Sarfaraz Khan. CFD applications in various heat exchangers design: a review. Applied Thermal Engineering 2012;32:1–12. [33] Abdelkrim Sehli, Abdelhafid Hasni, Mohammed Tamali. The potential of earth–air heat exchangers for low energy cooling of buildings in South Algeria. Energy Procedia 2012;18:496–506. [34] Cucumo M, Cucumo S, Montoro L, Vulcano A. A one-dimensional transient analytical model for earth-to-air heat exchangers, taking into account condensation phenomena and thermal perturbation from the upper free surface as well as around the buried pipes. Heat and Mass Transfer 2008;51: 506–16. [35] Badescu V. Simple and accurate model for the ground heat exchanger of a passive house. Renewable Energy 2007;32:845–55. [36] Mihalakakou G, Santamouris M, Asimakopoulos D, Tselepidaki I. Parametric prediction of the buried pipes cooling potential for passive cooling applications. Solar Energy 1995;55(3):163–73. [37] Lee Kwang Ho, Strand Richard K. The cooling and heating potential of an earth tube system in buildings. Energy and Buildings 2008;40:486–94. [38] Kabashnikov VP, Danilevskii LN, Nekrasov VP, Vityaz IP. Analytical and numerical investigation of the characteristics of a soil heat exchanger for ventilation systems. International Journal of Heat and Mass Transfer 2002;45: 2407–18. [39] Tittelein P, Achard G, Wurtz E. Modeling earth to air heat exchanger behavior with the convolutive response factor methods. Applied Energy 2009;86: 1683–91. [40] De Paepe M, Janssens A. Thermo-hydraulic design of earth–air heat exchangers. Energy and Buildings 2003;35:389–97. [41] Leyla Ozgener, Onder Ozgener. An experimental study of the exergetic performance of an underground air tunnel system for greenhouse cooling. Renewable Energy 2010;35:2804–11. [42] Onder Ozgener, Leyla Ozgener. Determining the optimal design of a closed loop earth to air heat exchanger for greenhouse heating by using exergoeconomics. Energy and Buildings 2011;43:960–5. [43] Ajmi FAl, Loveday DL, Hanby V. The cooling potential of earth–air heat exchangers for domestic buildings in a desert climate. Building and Environment 2006;41:235–44. [44] Woodson Thomas, Coulibaly Ye´zouma, Traore´ Eric Seydou. Earth–air heat exchangers for passive air conditioning: case study Burkina Faso. Journal of Construction in Developing Countries 2012;17(1):21–33. [45] Khalajzadeh Vahid, Farmahini-Farahani1Moien, Heidarinejad Ghassem. A novel integrated system of ground heat exchanger and indirect evaporative cooler. Energy and Buildings 2012;49:604–10. [46] Pfafferott J. Evaluation of earth-to-air heat exchangers with a standardized method to calculate energy efficiency. Energy and Buildings 2003;35(10): 971–83. [47] Thiers S, Peuportier P. Thermal and environmental assessment of a passive building equipped with an earth-to-air heat exchanger in France. Solar Energy 2008;82:820–31. [48] Hollmuller Pierre, Lachal Bernard. Cooling and preheating with buried pipe systems: monitoring, simulation and economic aspects. Energy and Buildings 2001;33:509–18. [49] Hamada Yasuhiro, Nakamura Makoto, Saitoh Hisashi, Kubota Hideki, Ochifuji Kiyoshi. Improved underground heat exchanger by using no-dig method for space heating and cooling. Renewable Energy 2007;32:480–95. [50] Breesch H, Bossaer A, Janssens A. Passive cooling in a low-energy office building. Solar Energy 2005;79:682–96. en_US
dc.identifier.uri http://hdl.handle.net/123456789/636
dc.description Supervised by Dr. Arafat Ahmed Bhuiyan en_US
dc.description.abstract Thermal performance of Earth Air Tunnel Heat Exchanger (EATHE) under steady operating conditions has been carried out considering in hot and dry region of Bangladesh using Computational Fluid Dynamics modeling. Effect of soil thermal conductivity and by changing air velocity operation of EATHE on thermal performance has been evaluated for different pipe length of EATHE using experimentally validated CFD. Simulation Results show that the steady thermal performance of EATHE is significantly dependent on thermal conductivity of the soil and velocity of air. Results show that the increase in flow velocity leads to change in thermal behavior of the pipe. The effect of soil thermal conductivity of EATHE on thermal performance has been also carried out for different pipe length of EATHE using experimentally validated CFD simulation. Maximum air temperature drop of 15.6, 17.0 and 17.3 K are observed for soil thermal conductivities of 0.52, 2 and 4 W m1 K1 respectively for 60 meter pipe. The thickness of the soil annulus beyond which no significant rise in temperature of soil observed is equal to the pipe diameter. Mainly in this paper, the effect soil thermal conductivity has been compared with different pipe length considering also the change in velocity of air. The optimization of pipe length has been also carried out from the experimental analysis based on validated CFD analysis. en_US
dc.language.iso en en_US
dc.publisher Department of Mechanical and Production Engineering, Islamic University of Technology, Board Bazar, Gazipur, Bangladesh en_US
dc.title Optimizing the length of Earth Air Tunnel Heat Exchanger based on CFD analysis en_US