Development of a High-sensitive Refractive Index and Temperature Nano-sensor

Show simple item record

dc.contributor.author Hassan, Md. Farhad
dc.date.accessioned 2021-02-15T08:31:15Z
dc.date.available 2021-02-15T08:31:15Z
dc.date.issued 2021-02-15
dc.identifier.citation [1] N. Kazanskiy, S. Khonina, and M. Butt, “Plasmonic sensors based on metalinsulator- metal waveguides for refractive index sensing applications: A brief review,” Physica E: Low-dimensional Systems and Nanostructures, vol. 117, p. 113798, 2020. [2] Z. Zhu, L. Liu, Z. Liu, Y. Zhang, and Y. Zhang, “Surface-plasmon-resonancebased optical-fiber temperature sensor with high sensitivity and high figure of merit,” Optics letters, vol. 42, no. 15, pp. 2948–2951, 2017. [3] H. Li, L. Lin, and S. Xie, “Refractive index of human whole blood with different types in the visible and near-infrared ranges,” in Laser-Tissue Interaction XI: Photochemical, Photothermal, and Photomechanical, vol. 3914. International Society for Optics and Photonics, 2000, pp. 517–521. [4] Y. Tang, Z. Zhang, R. Wang, Z. Hai, C. Xue, W. Zhang, and S. Yan, “Refractive index sensor based on fano resonances in metal-insulator-metal waveguides coupled with resonators,” Sensors, vol. 17, no. 4, p. 784, 2017. [5] Z. Zhang, J. Yang, X. He, J. Zhang, J. Huang, D. Chen, and Y. Han, “Plasmonic refractive index sensor with high figure of merit based on concentric-rings resonator,” Sensors, vol. 18, no. 1, p. 116, 2018. [6] M. Butt, N. Kazanskiy, and S. Khonina, “Highly integrated plasmonic sensor design for the simultaneous detection of multiple analytes,” Current Applied Physics, vol. 20, no. 11, pp. 1274–1280, 2020. [7] M. R. Rakhshani and M. A. Mansouri-Birjandi, “Engineering hexagonal array of nanoholes for high sensitivity biosensor and application for human blood group detection,” IEEE Transactions on Nanotechnology, vol. 17, no. 3, pp. 475–481, 2018. [8] ——, “High sensitivity plasmonic refractive index sensing and its application for human blood group identification,” Sensors and Actuators B: Chemical, vol. 249, pp. 168–176, 2017. 76 [9] N. Kazanskiy, M. Butt, and S. Khonina, “Nanodots decorated mim semiring resonator cavity for biochemical sensing applications,” Photonics and Nanostructures-Fundamentals and Applications, vol. 42, p. 100836, 2020. [10] Z. Chen, L. Yu, L. Wang, G. Duan, Y. Zhao, and J. Xiao, “A refractive index nanosensor based on fano resonance in the plasmonic waveguide system,” IEEE Photonics Technology Letters, vol. 27, no. 16, pp. 1695–1698, 2015. [11] M. Yahya and M. Saghir, “Empirical modelling to predict the refractive index of human blood,” Physics in Medicine & Biology, vol. 61, no. 4, p. 1405, 2016. [12] M. R. Rakhshani and M. A. Mansouri-Birjandi, “Dual wavelength demultiplexer based on metal–insulator–metal plasmonic circular ring resonators,” Journal of Modern Optics, vol. 63, no. 11, pp. 1078–1086, 2016. [13] A. D. Raki´c, A. B. Djuriši´c, J. M. Elazar, and M. L. Majewski, “Optical properties of metallic films for vertical-cavity optoelectronic devices,” Applied optics, vol. 37, no. 22, pp. 5271–5283, 1998. [14] W. L. Barnes, A. Dereux, and T. W. Ebbesen, “Surface plasmon subwavelength optics,” nature, vol. 424, no. 6950, pp. 824–830, 2003. [15] V. V. Temnov, G. Armelles, U. Woggon, D. Guzatov, A. Cebollada, A. Garcia- Martin, J.-M. Garcia-Martin, T. Thomay, A. Leitenstorfer, and R. Bratschitsch, “Active magneto-plasmonics in hybrid metal–ferromagnet structures,” Nature Photonics, vol. 4, no. 2, pp. 107–111, 2010. [16] D. K. Gramotnev and S. I. Bozhevolnyi, “Plasmonics beyond the diffraction limit,” Nature photonics, vol. 4, no. 2, pp. 83–91, 2010. [17] Y. Fang and M. Sun, “Nanoplasmonic waveguides: towards applications in integrated nanophotonic circuits,” Light: Science & Applications, vol. 4, no. 6, pp. e294–e294, 2015. [18] M. F. Hassan, R. H. Sagor, I. Tathfif, K. S. Rashid, and M. Radoan, “An optimized dielectric-metal-dielectric refractive index nanosensor,” IEEE Sensors Journal, vol. 21, no. 2, pp. 1461–1469, 2020. [19] M. Rahmatiyar, M. Afsahi, and M. Danaie, “Design of a refractive index plasmonic sensor based on a ring resonator coupled to a mim waveguide containing tapered defects,” Plasmonics, vol. 15, no. 6, pp. 2169–2176, 2020. [20] M. R. Rakhshani, “Optical refractive index sensor with two plasmonic doublesquare resonators for simultaneous sensing of human blood groups,” Photonics and Nanostructures-Fundamentals and Applications, vol. 39, p. 100768, 2020. 77 [21] Y.-J. Guo, K.-D. Xu, X. Deng, X. Cheng, and Q. Chen, “Millimeter-wave onchip bandpass filter based on spoof surface plasmon polaritons,” IEEE Electron Device Letters, vol. 41, no. 8, pp. 1165–1168, 2020. [22] E. Forati and G. W. Hanson, “Surface plasmon polaritons on soft-boundary graphene nanoribbons and their application in switching/demultiplexing,” Applied Physics Letters, vol. 103, no. 13, p. 133104, 2013. [23] R. H. Sagor, M. S. I. Sumon, and M. Tazwar, “Design and analysis of a novel air gap–based semi-elliptical nanoplasmonic coupler,” Plasmonics, vol. 14, no. 6, pp. 1993–2001, 2019. [24] Y.-F. C. Chau, “Mid-infrared sensing properties of a plasmonic metal–insulator– metal waveguide with a single stub including defects,” Journal of Physics D: Applied Physics, vol. 53, no. 11, p. 115401, 2020. [25] S. Zou, F. Wang, R. Liang, L. Xiao, and M. Hu, “A nanoscale refractive index sensor based on asymmetric plasmonic waveguide with a ring resonator: A review,” IEEE Sensors Journal, vol. 15, no. 2, pp. 646–650, 2014. [26] S. Ghorbani, M. Sadeghi, and Z. Adelpour, “A highly sensitive and compact plasmonic ring nano-biosensor for monitoring glucose concentration,” Laser Physics, vol. 30, no. 2, p. 026204, 2019. [27] R. H. Sagor, M. F. Hassan, S. Sharmin, T. Z. Adry, and M. A. R. Emon, “Numerical investigation of an optimized plasmonic on-chip refractive index sensor for temperature and blood group detection,” Results in Physics, vol. 19, p. 103611, 2020. [28] Z. Zhang, J. Yang, X. He, J. Zhang, J. Huang, D. Chen, and Y. Han, “Plasmonic refractive index sensor with high figure of merit based on concentric-rings resonator,” Sensors, vol. 18, no. 1, p. 116, 2018. [29] G. Qiu, Z. Gai, Y. Tao, J. Schmitt, G. A. Kullak-Ublick, and J. Wang, “Dualfunctional plasmonic photothermal biosensors for highly accurate severe acute respiratory syndrome coronavirus 2 detection,” ACS nano, vol. 14, no. 5, pp. 5268–5277, 2020. [30] S. Zou, F. Wang, R. Liang, L. Xiao, and M. Hu, “A nanoscale refractive index sensor based on asymmetric plasmonic waveguide with a ring resonator: A review,” IEEE Sensors Journal, vol. 15, no. 2, pp. 646–650, 2014. [31] G. Qiu, Z. Gai, Y. Tao, J. Schmitt, G. A. Kullak-Ublick, and J. Wang, “Dualfunctional plasmonic photothermal biosensors for highly accurate severe acute respiratory syndrome coronavirus 2 detection,” ACS nano, vol. 14, no. 5, pp. 5268–5277, 2020. 78 [32] M. A. Jabin, K. Ahmed, M. J. Rana, B. K. Paul, M. Islam, D. Vigneswaran, and M. S. Uddin, “Surface plasmon resonance based titanium coated biosensor for cancer cell detection,” IEEE Photonics J, vol. 11, no. 4, pp. 1–10, 2019. [33] R. H. Sagor, M. F. Hassan, A. A. Yaseer, E. Surid, and M. I. Ahmed, “Highly sensitive refractive index sensor optimized for blood group sensing utilizing the fano resonance,” Applied Nanoscience, pp. 1–14, 2020. [34] K. Ahmed, F. Ahmed, S. Roy, B. K. Paul, M. N. Aktar, D. Vigneswaran, and M. S. Islam, “Refractive index-based blood components sensing in terahertz spectrum,” IEEE Sensors Journal, vol. 19, no. 9, pp. 3368–3375, 2019. [35] C.-Y. Tan and Y.-X. Huang, “Dependence of refractive index on concentration and temperature in electrolyte solution, polar solution, nonpolar solution, and protein solution,” Journal of Chemical & Engineering Data, vol. 60, no. 10, pp. 2827–2833, 2015. [36] K. E. You, N. Uddin, T. H. Kim, Q. H. Fan, and H. J. Yoon, “Highly sensitive detection of biological substances using microfluidic enhanced fabry-perot etalon-based optical biosensors,” Sensors and Actuators B: Chemical, vol. 277, pp. 62–68, 2018. [37] A. K. Sharma, R. Jha, H. S. Pattanaik, and G. J. Mohr, “Design considerations for surface plasmon resonance-based fiber-optic detection of human blood group,” Journal of biomedical optics, vol. 14, no. 6, p. 064041, 2009. [38] H. H. Goldstine and A. Goldstine, “The electronic numerical integrator and computer (eniac),” IEEE Annals of the History of Computing, vol. 18, no. 1, pp. 10–16, 1996. [39] T. Haigh, P. M. Priestley, M. Priestley, and C. Rope, ENIAC in action: Making and remaking the modern computer. MIT press, 2016. [40] D. A. B. Miller and H. M. Ozaktas, “Limit to the bit-rate capacity of electrical interconnects from the aspect ratio of the system architecture,” Journal of parallel and distributed computing, vol. 41, no. 1, pp. 42–52, 1997. [41] M. Horowitz, C.-K. K. Yang, and S. Sidiropoulos, “High-speed electrical signaling: Overview and limitations,” IEEE Micro, vol. 18, no. 1, pp. 12–24, 1998. [42] S. C. Esener, “Implementation and prospects for chip-to-chip free-space optical interconnects,” in International Electron Devices Meeting. Technical Digest (Cat. No. 01CH37224). IEEE, 2001, pp. 23–5. [43] B. Hecht, H. Bielefeldt, L. Novotny, Y. Inouye, and D. Pohl, “Local excitation, scattering, and interference of surface plasmons,” Physical review letters, vol. 77, no. 9, p. 1889, 1996. 79 [44] M. Butt, N. Kazanskiy, and S. Khonina, “Nanodots decorated asymmetric metal–insulator–metal waveguide resonator structure based on fano resonances for refractive index sensing application,” Laser Physics, vol. 30, no. 7, p. 076204, 2020. [45] Y. Tang, Z. Zhang, R. Wang, Z. Hai, C. Xue, W. Zhang, and S. Yan, “Refractive index sensor based on fano resonances in metal-insulator-metal waveguides coupled with resonators,” Sensors, vol. 17, no. 4, p. 784, 2017. [46] N. Amoosoltani, N. Yasrebi, A. Farmani, and A. Zarifkar, “A plasmonic nanobiosensor based on two consecutive disk resonators and unidirectional reflectionless propagation effect,” IEEE Sensors Journal, 2020. [47] M. A. A. Butt and N. Kazanskiy, “Enhancing the sensitivity of a standard plasmonic mim square ring resonator by incorporating the nano-dots in the cavity,” Photonics Letters of Poland, vol. 12, no. 1, pp. 1–3, 2020. [48] B. Ni, X. Chen, D. Xiong, H. Liu, G. Hua, J. Chang, J. Zhang, and H. Zhou, “Infrared plasmonic refractive index-sensitive nanosensor based on electromagnetically induced transparency of waveguide resonator systems,” Optical and Quantum Electronics, vol. 47, no. 6, pp. 1339–1346, 2015. [49] S.-B. Yan, L. Luo, C.-Y. Xue, and Z.-D. Zhang, “A refractive index sensor based on a metal-insulator-metal waveguide-coupled ring resonator,” Sensors, vol. 15, no. 11, pp. 29 183–29 191, 2015. [50] R. Zafar and M. Salim, “Enhanced figure of merit in fano resonance-based plasmonic refractive index sensor,” IEEE Sensors Journal, vol. 15, no. 11, pp. 6313– 6317, 2015. [51] Z. Chen, L. Yu, L. Wang, G. Duan, Y. Zhao, and J. Xiao, “A refractive index nanosensor based on fano resonance in the plasmonic waveguide system,” IEEE Photonics Technology Letters, vol. 27, no. 16, pp. 1695–1698, 2015. [52] Y.-Y. Xie, Y.-X. Huang, W.-L. Zhao, W.-H. Xu, and C. He, “A novel plasmonic sensor based on metal–insulator–metal waveguide with side-coupled hexagonal cavity,” IEEE Photonics Journal, vol. 7, no. 2, pp. 1–12, 2015. [53] X. Zhang, M. Shao, and X. Zeng, “High quality plasmonic sensors based on fano resonances created through cascading double asymmetric cavities,” Sensors, vol. 16, no. 10, p. 1730, 2016. [54] Z. Zhang, L. Luo, C. Xue, W. Zhang, and S. Yan, “Fano resonance based on metal-insulator-metal waveguide-coupled double rectangular cavities for plasmonic nanosensors,” Sensors, vol. 16, no. 5, p. 642, 2016. 80 [55] F. Chen and D. Yao, “Realizing of plasmon fano resonance with a metal nanowall moving along mim waveguide,” Optics Communications, vol. 369, pp. 72–78, 2016. [56] L. Chen, Y. Liu, Z. Yu, D.Wu, R. Ma, Y. Zhang, and H. Ye, “Numerical analysis of a near-infrared plasmonic refractive index sensor with high figure of merit based on a fillet cavity,” Optics express, vol. 24, no. 9, pp. 9975–9983, 2016. [57] M. R. Rakhshani and M. A. Mansouri-Birjandi, “High-sensitivity plasmonic sensor based on metal–insulator–metal waveguide and hexagonal-ring cavity,” IEEE Sensors Journal, vol. 16, no. 9, pp. 3041–3046, 2016. [58] C. Wu, H. Ding, T. Huang, X. Wu, B. Chen, K. Ren, and S. Fu, “Plasmoninduced transparency and refractive index sensing in side-coupled stub-hexagon resonators,” Plasmonics, vol. 13, no. 1, pp. 251–257, 2018. [59] J. Zhou, H. Chen, Z. Zhang, J. Tang, J. Cui, C. Xue, and S. Yan, “Transmission and refractive index sensing based on fano resonance in mim waveguidecoupled trapezoid cavity,” AIP Advances, vol. 7, no. 1, p. 015020, 2017. [60] A. Akhavan, H. Ghafoorifard, S. Abdolhosseini, and H. Habibiyan, “Plasmoninduced transparency based on a triangle cavity coupled with an ellipse-ring resonator,” Applied optics, vol. 56, no. 34, pp. 9556–9563, 2017. [61] M. R. Rakhshani and M. A. Mansouri-Birjandi, “Utilizing the metallic nanorods in hexagonal configuration to enhance sensitivity of the plasmonic racetrack resonator in sensing application,” Plasmonics, vol. 12, no. 4, pp. 999– 1006, 2017. [62] M. Butt, S. Khonina, and N. Kazanskiy, “Hybrid plasmonic waveguide-assisted metal–insulator–metal ring resonator for refractive index sensing,” Journal of Modern Optics, vol. 65, no. 9, pp. 1135–1140, 2018. [63] A. Akhavan, H. Ghafoorifard, S. Abdolhosseini, and H. Habibiyan, “Metal– insulator–metal waveguide-coupled asymmetric resonators for sensing and slow light applications,” IET Optoelectronics, vol. 12, no. 5, pp. 220–227, 2018. [64] R. Zafar, S. Nawaz, G. Singh, A. d’Alessandro, and M. Salim, “Plasmonicsbased refractive index sensor for detection of hemoglobin concentration,” IEEE Sensors Journal, vol. 18, no. 11, pp. 4372–4377, 2018. [65] X. Zhang, Y. Qi, P. Zhou, H. Gong, B. Hu, and C. Yan, “Refractive index sensor based on fano resonances in plasmonic waveguide with dual side-coupled ring resonators,” Photonic Sensors, vol. 8, no. 4, pp. 367–374, 2018. 81 [66] M. J. Al Mahmod, R. Hyder, and M. Z. Islam, “A highly sensitive metal– insulator–metal ring resonator-based nanophotonic structure for biosensing applications,” IEEE Sensors Journal, vol. 18, no. 16, pp. 6563–6568, 2018. [67] S. Ghorbani, M. A. Dashti, and M. Jabbari, “Plasmonic nano-sensor based on metal-dielectric-metal waveguide with the octagonal cavity ring,” Laser Physics, vol. 28, no. 6, p. 066208, 2018. [68] X. Yi, J. Tian, and R. Yang, “Tunable fano resonance in mdm stub waveguide coupled with a u-shaped cavity,” The European Physical Journal D, vol. 72, no. 4, p. 60, 2018. [69] M. Danaie and A. Shahzadi, “Design of a high-resolution metal–insulator–metal plasmonic refractive index sensor based on a ring-shaped si resonator,” Plasmonics, vol. 14, no. 6, pp. 1453–1465, 2019. [70] M. Butt, S. Khonina, and N. Kazanskiy, “A plasmonic colour filter and refractive index sensor applications based on metal–insulator–metal square micro-ring cavities,” Laser Physics, vol. 30, no. 1, p. 016205, 2019. [71] Y. Zhang and M. Cui, “Refractive index sensor based on the symmetric mim waveguide structure,” Journal of Electronic Materials, vol. 48, no. 2, pp. 1005– 1010, 2019. [72] M. Butt, S. Khonina, and N. Kazanskiy, “Plasmonic refractive index sensor based on metal–insulator-metal waveguides with high sensitivity,” Journal of Modern Optics, vol. 66, no. 9, pp. 1038–1043, 2019. [73] Z. Li, K. Wen, L. Chen, L. Lei, J. Zhou, D. Zhou, Y. Fang, and B. Wu, “Control of multiple fano resonances based on a subwavelength mim coupled cavities system,” IEEE Access, vol. 7, pp. 59 369–59 375, 2019. [74] X. Yang, E. Hua, M. Wang, Y. Wang, F. Wen, and S. Yan, “Fano resonance in a mim waveguide with two triangle stubs coupled with a split-ring nanocavity for sensing application,” Sensors, vol. 19, no. 22, p. 4972, 2019. [75] M. F. Hassan, M. M. Hasan, M. I. Ahmed, and R. H. Sagor, “Numerical investigation of a plasmonic refractive index sensor based on rectangular mim topology,” in 2020 International Seminar on Intelligent Technology and Its Applications (ISITIA). IEEE, 2020, pp. 77–82. [76] M. F. Hassan, I. Tathfif, M. Radoan, and R. H. Sagor, “A concentric double-ring resonator based plasmonic refractive index sensor with glucose sensing capability,” in 2020 IEEE REGION 10 CONFERENCE (TENCON). IEEE, 2020, pp. 91–96. 82 [77] M. Bazgir, M. Jalalpour, F. B. Zarrabi, and A. S. Arezoomand, “Design of an optical switch and sensor based on a mim coupled waveguide using a dna composite,” Journal of Electronic Materials, vol. 49, no. 3, pp. 2173–2178, 2020. [78] M. R. Rakhshani and M. A. Mansouri-Birjandi, “A high-sensitivity sensor based on three-dimensional metal–insulator–metal racetrack resonator and application for hemoglobin detection,” Photonics and Nanostructures-Fundamentals and Applications, vol. 32, pp. 28–34, 2018. [79] K. E. You, N. Uddin, T. H. Kim, Q. H. Fan, and H. J. Yoon, “Highly sensitive detection of biological substances using microfluidic enhanced fabry-perot etalon-based optical biosensors,” Sensors and Actuators B: Chemical, vol. 277, pp. 62–68, 2018. [80] M. R. Rakhshani, “Fano resonances based on plasmonic square resonator with high figure of merits and its application in glucose concentrations sensing,” Optical and Quantum Electronics, vol. 51, no. 9, pp. 1–16, 2019. [81] C. S. Desai and J. F. Abel, Introduction to the finite element method; a numerical method for engineering analysis. Van Nostrand Reinhold, 1971. [82] M. N. Sadiku, Numerical techniques in electromagnetics with MATLAB. CRC press, 2018. [83] D. G. Rabus, Integrated ring resonators. Springer, 2007. [84] M. Butt, S. Khonina, and N. Kazanskiy, “Plasmonic refractive index sensor based on mim square ring resonator,” in 2018 International Conference on Computing, Electronic and Electrical Engineering (ICE Cube). IEEE, 2018, pp. 1–4. [85] N. Kazanskiy, M. Butt, and S. Khonina, “Nanodots decorated mim semiring resonator cavity for biochemical sensing applications,” Photonics and Nanostructures-Fundamentals and Applications, vol. 42, p. 100836, 2020. [86] W. K. Jung and K. M. Byun, “Fabrication of nanoscale plasmonic structures and their applications to photonic devices and biosensors,” Biomedical Engineering Letters, vol. 1, no. 3, p. 153, 2011. [87] S.-W. Lee, K.-S. Lee, J. Ahn, J.-J. Lee, M.-G. Kim, and Y.-B. Shin, “Highly sensitive biosensing using arrays of plasmonic au nanodisks realized by nanoimprint lithography,” ACS nano, vol. 5, no. 2, pp. 897–904, 2011. [88] R. H. Sagor, M. F. Hassan, A. A. Yaseer, E. Surid, and M. I. Ahmed, “Highly sensitive refractive index sensor optimized for blood group sensing utilizing the fano resonance,” Applied Nanoscience, pp. 1–14, 2020. 83 [89] Z. Zhang, J. Yang, X. He, J. Zhang, J. Huang, D. Chen, and Y. Han, “Plasmonic refractive index sensor with high figure of merit based on concentric-rings resonator,” Sensors, vol. 18, no. 1, p. 116, 2018. [90] K. V. Voronin, Y. V. Stebunov, A. A. Voronov, A. V. Arsenin, and V. S. Volkov, “Vertically coupled plasmonic racetrack ring resonator for biosensor applications,” Sensors, vol. 20, no. 1, p. 203, 2020. [91] M. Butt, N. Kazanskiy, and S. Khonina, “Nanodots decorated asymmetric metal–insulator–metal waveguide resonator structure based on fano resonances for refractive index sensing application,” Laser Physics, vol. 30, no. 7, p. 076204, 2020. [92] T.Wu, Y. Liu, Z. Yu, H. Ye, Y. Peng, C. Shu, C. Yang,W. Zhang, and H. He, “A nanometeric temperature sensor based on plasmonic waveguide with an ethanolsealed rectangular cavity,” Optics Communications, vol. 339, pp. 1–6, 2015. [93] J. E. Hall and M. E. Hall, Guyton and Hall textbook of medical physiology e- Book. Elsevier Health Sciences, 2020. [94] K. E. Barrett, S. Boitano, S. M. Barman, and H. L. Brooks, “Ganong’s review of medical physiology twenty,” 2010. [95] M. Amasia and M. Madou, “Large-volume centrifugal microfluidic device for blood plasma separation,” Bioanalysis, vol. 2, no. 10, pp. 1701–1710, 2010. [96] A. W. Mohammad, R. K. Basha, and C. P. Leo, “Nanofiltration of glucose solution containing salts: Effects of membrane characteristics, organic component and salts on retention,” Journal of Food Engineering, vol. 97, no. 4, pp. 510– 518, 2010. [97] X.-L.Wang,W.-N.Wang, and D.-X.Wang, “Experimental investigation on separation performance of nanofiltration membranes for inorganic electrolyte solutions,” Desalination, vol. 145, no. 1-3, pp. 115–122, 2002. [98] N. Branch and R. L. Jones, “Laboratory procedure manual,” 2008. [99] J. Y. Zhang, J. Do,W. R. Premasiri, L. D. Ziegler, and C. M. Klapperich, “Rapid point-of-care concentration of bacteria in a disposable microfluidic device using meniscus dragging effect,” Lab on a Chip, vol. 10, no. 23, pp. 3265–3270, 2010. [100] B. Timmer, K. Van Delft, W. Olthuis, P. Bergveld, and A. van den Berg, “Micro-evaporation electrolyte concentrator,” Sensors and Actuators B: Chemical, vol. 91, no. 1-3, pp. 342–346, 2003. [101] C.-Y. Tan and Y.-X. Huang, “Dependence of refractive index on concentration and temperature in electrolyte solution, polar solution, nonpolar solution, and 84 protein solution,” Journal of Chemical & Engineering Data, vol. 60, no. 10, pp. 2827–2833, 2015. [102] R. R. Singh, S. Kumari, A. Gautam, and V. Priye, “Glucose sensing using slot waveguide-based soi ring resonator,” IEEE Journal of Selected Topics in Quantum Electronics, vol. 25, no. 1, pp. 1–8, 2018. 85 en_US
dc.identifier.uri http://hdl.handle.net/123456789/808
dc.description Supervised by Dr. Rakibul Hasan Sagor, Associate Professor, Electrical and Electronic Engineering Department, Islamic University of Technology (IUT), Gazipur. en_US
dc.description.abstract High perform lab-on-chip sensors packaged in a miniaturized form are replacing the bulky sensors in the point-of-care detection and allowing rapid triage, treatment, or discharge of patients. To satisfy the requirements of label-free detection, low cost, fast response of a lab-on-chip biosensor, a nanodot enhanced metal-insulator-metal (MIM) waveguide based refractive index sensor coupled with three rectangular cavities, is proposed in this work. Numerical investigation of the transmission spectra, employing the finite element method (FEM), exhibits a linear correspondence with the refractive index, which is used to sense the unknown materials. With the initial structural setup, the proposed sensor demonstrates a maximum sensitivity and FOM as 5016 nmRIU􀀀1 and 144, respectively. Imposing a sequential optimization of the structural parameters and enhancing light-matter interaction by loading nanodots at the high E-field confined areas, desired sensitivity (S) and figure of merit (FOM) are upgraded to 7564 nmRIU􀀀1 and 120, respectively. The proposed sensor’s temperature sensing capability is explored by filling the sensing media with alcohol and polydimethylsiloxane (PDMS). Maximum temperature sensitivity of 2:68 nm0C􀀀1 operating from 􀀀1000C to 600C is recorded, while for polydimethylsiloxane, the maximum temperature sensitivity of 3:40 nm0C􀀀1 for 200C to 700C operating range is recorded. Furthermore, this work addresses some recent plasmonic sensors’ shortcomings in the selective detection of a single element from a complex solution (e.g., blood sample) and proposed a sample preparation model combining purification, molecular separation, and concentration enhancement prior to the selective detection of Na+, K+, and glucose concentration in the human blood. A refractive index model for this purpose, is developed that exposes a maximum shift of 0:83 nm, 1:23 nm, and 8:72 nm of the transmittance peak for the concentration variation of 1 mgdL􀀀1 in Na+, K+, and glucose solution easily differentiable by the modern spectrometer. With such excellent performance metrics, compact size, and simple to use feature, the proposed sensor is expected to bring a notable solution in the point-of-care detection. en_US
dc.language.iso en en_US
dc.publisher Department of Electrical and Electronic Engineering, Islamic University of Technology,Board Bazar, Gazipur, Bangladesh en_US
dc.title Development of a High-sensitive Refractive Index and Temperature Nano-sensor en_US
dc.type Thesis en_US