Design, Construction and study of performance of a flat-plate solar heater for winter air conditioning of a small residential building in Bangladesh

Show simple item record

dc.contributor.author Haq, Mahmud Arefin
dc.contributor.author Rashid, Adib bin
dc.date.accessioned 2021-09-08T06:09:00Z
dc.date.available 2021-09-08T06:09:00Z
dc.date.issued 2013-11-15
dc.identifier.citation [1]Akpinar, E.K., Sarsılmaz, C., Yıldız, C., 2004. Mathematical modeling of a thin layer drying of apricots in a solar energized rotary dryer. International Journal of Energy Research 28, 739-52. [2]Akpinar, E.,K., Kocyigit,F. 2010. Experimental investigation of thermal performance of solar air heater having different obstacles on absorber plates. International Cominications in Heat and Mass Transfer 37, 416-421 [3]Aboul-Enein S., El-Sebaii A.A., Ramadan M.R.I., El-Gohary H.G. 2000. Parametric study of a solar air heater with and without thermal storage for solar drying applications. Renewable Energy 21, 505-522 [4]Aldabbagh, L.B.Y., Egelioglu, F., lkan, M., 2010. Single and double pass solar air heaters with wire mesh as packing bed. Energy 35, 3783-3787. [5]Alok Chaube, Sahoo, P.K.,and Solanki S.C. 2006. Analysis of heat transfer augmentation and flow characteristics due to rib roughness over absorber plate of a solar air heater. Renewable Energy 31, 317-331 [6]Alvarez, A., Cabeza, O., Muniz, M.C., Varela, L.M., 2010. Experimental and numerical investigation of a flat-plate solarcollector. Energy 35, 3707-3716 [7]Yeh,Ho-Ming, and Ho, Chii-Dong, 2009. Effect of external recycle on the performances of flat-plate solar air heaters with internal fins attached. Renewable Energy 34,1340-1347. [8]Yeh, Ho-Ming, Ho, Chii-Dong, 2009. Solar air heaters with external recycle Applied Thermal Engineering 29 1694-1701. [9]El-Sebaii, A.A., Aboul-Enein, S., Ramadan, M. R. I., El-Bialy, E., 2007, Year round performance of double pass solar air heater with packed bed. Energy Convers Manage 48, 990-1003. [10]Esen, H., 2008. Experimental energy and exergy analysis of a double-flow SAH having different obstacles on absorber plates. Build Environ 43, 1046-1054. [11]Flores-Irigollen A. Ferna´ndez J.L., Rubio-Cerda . b, E. Poujol, F.T., 2004, Heat transfer dynamics in an inflatable-tunnel solar air heater. Renewable Energy 29, 1367- 1382 [12]Garg,H.P. and Adhikari R.S., 1999. Performance Evaluation of a single solar air heater with N-Subcollectors Connected in Different combination. Int. J. Energy Res., 23, 30 403-414 [13]Goswami D.Y., Kreith F., Kreider J.F, 2000. Principles of Solar Engineering 2nd edition. Philadelphia, PA. Taylor and francis. [14]Gupta, M.K., Kaushik, S.C., 2009. Performance evaluation of solar air heater for various artificial roughness geometries based on energy, effective and exergy efficiencies. Renewable Energy 34, 465-476. [15]Hans, V. S., Saini R.P., Saini, J.S. 2009. Performance of artificially roughened solar air heaters-A review. Renewable and Sustainable Energy Reviews 13,1854-1869 en_US
dc.identifier.uri http://hdl.handle.net/123456789/878
dc.description Supervised by Professor Dr. A.K.M. Iqbal Hussain, Department of Mechanical & Chemical Engineering (MCE), Islamic University of Technology (IUT), OIC, Board Bazar, Gazipur. en_US
dc.description.abstract Rising costs of conventional fuels, increasing energy demand, concerns over climate change and pollutants resulted from burning fossil fuels have increased the interest in various renewable energy technologies. The energy demand associated with heated air for different sectors is quite significant. Solar air heaters have been developed with the aim of reducing the demand for conventional fuels. This Thesis presents design and technical evaluation of solar air heating system on a small residential building in Bangladesh for winter air conditioning. It is estimated that for heating of 3m x 3m x 3.5m of room, a collector of 1.5m2 is needed with proper insulation of 2 inch thick Fiber glass. For the surface coating (generally black) on a mild steel sheet a selective coating system is suggested. For the distribution of air in the conditioned space a blower of Pressure 55mm (water), 1400 RPM, Frequency 50Hz, air velocity of 12 m/s and air capacity of .4 m3/s is used. A double glazing system is used to minimize the heat losses from the collector plate, which occur due to convection and radiation. The experimental work was performed beside the middle workshop, Mechanical Engineering Department, Islamic University of Technology under Gazipur prevailing weather conditions during the summer months August and September. Data were collected on half an hour interval from 9.00 am to 5.00 pm. As the ground was flat, the collector was proposed to be tilted with 23.5°. The outlet, Tout, and the inlet, Tin, temperatures were measured by using T- type thermocouples and the global solar radiation incident on an inclined surface was measured by using a Pyranometer. en_US
dc.language.iso en en_US
dc.publisher Department of Mechanical and Production Engineering (MPE),Islamic University of Technology(IUT), Board Bazar, Gazipur, Bangladesh en_US
dc.subject Renewable energy, Human comfort, winter air conditioning, Solar air heaters, thermal efficiency en_US
dc.title Design, Construction and study of performance of a flat-plate solar heater for winter air conditioning of a small residential building in Bangladesh en_US
dc.type Thesis en_US